<?xml version="1.0" encoding="utf-8"?>
<!DOCTYPE article
  PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.1 20151215//EN" "https://jats.nlm.nih.gov/publishing/1.1/JATS-journalpublishing1.dtd">
<article article-type="research-article" dtd-version="1.1" specific-use="sps-1.8" xml:lang="es" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">
	<front>
		<journal-meta>
			<journal-id journal-id-type="publisher-id">infraestructura</journal-id>
			<journal-title-group>
				<journal-title>Infraestructura Vial</journal-title>
				<abbrev-journal-title abbrev-type="publisher">Infraestructura Vial</abbrev-journal-title>
			</journal-title-group>
			<issn pub-type="ppub">2215-3705</issn>
			<issn pub-type="epub">2215-3705</issn>
			<publisher>
				<publisher-name>Universidad de Costa Rica, Laboratorio Nacional de Materiales y Modelos Estructurales</publisher-name>
			</publisher>
		</journal-meta>
		<article-meta>
			<article-id pub-id-type="doi">10.15517/mym.v12i0.46889</article-id>
			<article-categories>
				<subj-group subj-group-type="heading">
					<subject>Artículo científico</subject>
				</subj-group>
			</article-categories>
			<title-group>
				<article-title>Graduación para un agregado grueso con tamaño máximo nominal de 16 mm</article-title>
				<trans-title-group xml:lang="en">
					<trans-title>Grading for a coarse- aggregate with a maximum nominal size of 16 mm</trans-title>
				</trans-title-group>
			</title-group>
			<contrib-group>
				<contrib contrib-type="author">
					<name>
						<surname>Chacón Bolívar</surname>
						<given-names>Valeria</given-names>
					</name>
					<xref ref-type="aff" rid="aff1"><sup>1</sup></xref>
				</contrib>
				<contrib contrib-type="author">
					<name>
						<surname>Muñoz Umaña</surname>
						<given-names>Flor de María</given-names>
					</name>
					<xref ref-type="aff" rid="aff2"><sup>2</sup></xref>
				</contrib>
				<contrib contrib-type="author">
					<name>
						<surname>Rodríguez Rojas</surname>
						<given-names>Einer</given-names>
					</name>
					<xref ref-type="aff" rid="aff3"><sup>3</sup></xref>
				</contrib>
			</contrib-group>
			<aff id="aff1">
				<label>1</label>
				<institution content-type="original">Estudiante, Escuela de Ingeniería Civil; Universidad de Costa Rica, San José, Costa Rica; valeria.chaconbolivar@ucr.ac.cr</institution>
				<institution content-type="normalized">Universidad de Costa Rica</institution>
				<institution content-type="orgdiv1">Escuela de Ingeniería Civil;</institution>
				<institution content-type="orgname">Universidad de Costa Rica,</institution>
				<addr-line>
					<city>San José,</city>
				</addr-line>
				<country country="CR">Costa Rica</country>
				<email>valeria.chaconbolivar@ucr.ac.cr</email>
			</aff>
			<aff id="aff2">
				<label>2</label>
				<institution content-type="original">Profesora catedrática, Escuela de Ingeniería Civil; Universidad de Costa Rica, San José, Costa Rica; flor.munoz@ucr.ac.cr</institution>
				<institution content-type="normalized">Universidad de Costa Rica</institution>
				<institution content-type="orgdiv1">Escuela de Ingeniería Civil;</institution>
				<institution content-type="orgname">Universidad de Costa Rica,</institution>
				<addr-line>
					<city>San José,</city>
				</addr-line>
				<country country="CR">Costa Rica</country>
				<email>flor.munoz@ucr.ac.cr</email>
			</aff>
			<aff id="aff3">
				<label>3</label>
				<institution content-type="original">Profesor, Escuela de Ingeniería Civil; Universidad de Costa Rica, San José, Costa Rica; einer.rodríguez@ucr.ac.cr</institution>
				<institution content-type="normalized">Universidad de Costa Rica</institution>
				<institution content-type="orgdiv1">Escuela de Ingeniería Civil;</institution>
				<institution content-type="orgname">Universidad de Costa Rica,</institution>
				<addr-line>
					<city>San José,</city>
				</addr-line>
				<country country="CR">Costa Rica</country>
				<email>einer.rodríguez@ucr.ac.cr</email>
			</aff>
			<pub-date pub-type="collection">
				<day>01</day>
				<season>Jan-Dec</season>
				<year>2023</year>
			</pub-date>
			<volume>13</volume>
			<issue>1</issue>
			<fpage>13</fpage>
			<lpage>23</lpage>
			<history>Fecha de recepción: <date date-type="received">
					<day>06</day>
					<month>05</month>
					<year>2022</year>
				</date> / Fecha de aprobación:<date date-type="accepted">
					<day>30</day>
					<month>06</month>
					<year>2023</year>
				</date>
			</history>
			<permissions>
				<license license-type="open-access" xlink:href="https://creativecommons.org/licenses/by-nc/3.0/" xml:lang="es">
					<license-p>Este es un artículo publicado en acceso abierto bajo una licencia Creative Commons</license-p>
				</license>
			</permissions>
			<abstract>
				<title>Resumen</title>
				<p>En Costa Rica, la normativa de mayor empleo en materia de especificaciones para valorar la calidad de los agregados para concreto hidráulico, corresponde a la de la Sociedad Americana de Pruebas y Materiales (ASTM, por sus siglas en inglés), las cuales constituyen la base de las normas del Instituto de Normas Técnicas de Costa Rica (INTECO).</p>
				<p>Por ende, los requerimientos de graduación de los agregados que se sigue en el país provienen de la norma <xref ref-type="bibr" rid="B12">ASTM C33 (2018)</xref> Especificación normalizada para agregados para concreto. Para el diseño de mezclas, esta norma proporciona especificaciones granulométricas para tamaños máximos nominales de 90 mm, 63 mm, 50 mm, 37,5 mm, 25 mm, 19 mm, 12,7 mm y 9,5 mm.</p>
				<p>No obstante, en estudios recientes, <xref ref-type="bibr" rid="B19">Hernández (2018)</xref> y <xref ref-type="bibr" rid="B18">Delgado (2018)</xref>, utilizaron un agregado con tamaño máximo nominal de 16 mm en la elaboración de concreto hidráulico para obtener curvas estándar de desarrollo de resistencia para diferentes tipos de cemento portland que se comercializan en el país. En sus trabajos, tanto Hernández (2018) como Delgado (2018), utilizaron agregado grueso de río y agregado grueso de tajo. Para cada caso se usó como referencia granulométrica las especificaciones para tamaños máximos nominales de 12,7 mm y 19 mm que proporciona la norma ASTM C33 (2018), dado que en esta norma no existen especificaciones para agregado de 16 mm. </p>
				<p>Fuentes productoras de agregados a nivel nacional están generando una cantidad importante de agregado de 16 mm, por lo que resultó de interés realizar un estudio experimental con muestras estadísticamente válidas, que permitan comprobar con un grado de certeza adecuado la validez de usar la granulometría que mejor se ajuste (tamaño máximo nominal: 12,7 mm o 19 mm) cuando se emplea agregado de 16 mm. Pero también, como parte del estudio, se generó una propuesta de límites granulométricos para un tamaño de 16 mm.</p>
			</abstract>
			<trans-abstract xml:lang="en">
				<title>Abstract</title>
				<p>In Costa Rica, the most widely used standard in terms of specifications to assess the quality of aggregates for hydraulic concrete corresponds to that of the American Society for Testing and Materials (ASTM), which constitutes the basis for of the standards of the Institute of Technical Standards of Costa Rica (INTECO).</p>
				<p>Therefore, the graduation requirements of the aggregates that are followed in the country come from the ASTM C33 (2018) standard Specification for aggregates for concrete. For mix design, this standard provides grading specifications for nominal maximum sizes of 90 mm, 63 mm, 50 mm, 37,5 mm, 25 mm, 19 mm, 12,7mm and 9,5 mm .</p>
				<p>However, in recent studies, Hernández (2018) and Delgado (2018), used an aggregate with a nominal maximum size of 16 mm in the production of hydraulic concrete to obtain standard resistance development curves for different types of portland cement that are marketed in the country. In their work, both Hernández (2018) and Delgado (2018) used coarse river aggregate and coarse pit aggregate. For each case, the specifications for maximum nominal sizes of 12,7 mm and 19 mm provided by the ASTM C33 (2018) standard were used as granulometric reference, since in this standard there are no specifications for aggregate of 16 mm. </p>
				<p>Aggregate-producing sources at the national level are generating a significant amount of 16 mm aggregate, so it was interesting to carry out an experimental study with statistically valid samples, which allow verifying with an adequate degree of certainty the validity of using the granulometry that best will fit (nominal maximum size: 12,7mm or 19 mm) when using 16 mm aggregate. But also, as part of the study, a proposal for granulometric limits was generated for a size of 16 mm.</p>
			</trans-abstract>
			<kwd-group xml:lang="es">
				<title>Palabras clave:</title>
				<kwd>granulometría</kwd>
				<kwd>agregado grueso</kwd>
				<kwd>tamaño máximo</kwd>
				<kwd>concreto</kwd>
			</kwd-group>
			<kwd-group xml:lang="en">
				<title>Key words:</title>
				<kwd>grading</kwd>
				<kwd>coarse aggregate</kwd>
				<kwd>maximum size</kwd>
				<kwd>concrete</kwd>
			</kwd-group>
			<counts>
				<fig-count count="8"/>
				<table-count count="9"/>
				<equation-count count="0"/>
				<ref-count count="19"/>
				<page-count count="11"/>
			</counts>
		</article-meta>
	</front>
	<body>
		<sec sec-type="intro">
			<title>Introducción</title>
			<p>A nivel nacional, productoras de agregados generan y comercializan agregado con tamaño máximo nominal de 16 mm, y brindan a los usuarios información sobre la distribución granulométrica que posee su producto; sin embargo, solo es posible cotejar esta información contra las especificaciones correspondientes a tamaños máximos nominales de 12,7 mm o 19 mm de la norma ASTM C33 (2018), dado que esta carece de especificaciones granulométricas para agregado de 16 mm.</p>
			<p>
				<xref ref-type="bibr" rid="B19">Hernández (2018</xref>), generó curvas de desarrollo de resistencia a compresión simple de concreto hidráulico usando como “variable de estudio” tres tipos de cementos modificados (MM/C (P-C)-28, MM/C (C-P)-28, MC/A-AR). Para la producción del concreto empleó agregado de río y agregado de tajo, ambos con tamaño máximo nominal de 16 mm. Como parte del estudio realizó la caracterización granulométrica del agregado, y al no existir especificaciones para este tamaño, contrastó la curva granulométrica obtenida con los límites de agregado de 12,7 mm y con los de agregado de 19 mm, siendo la primera la que mejor se ajustó para el agregado de tajo y la segunda para el agregado de río; los resultados obtenidos por Hernández se muestran en la <xref ref-type="fig" rid="f1">Figura 1</xref>.</p>
			<p>
				<fig id="f1">
					<label>Figura 1</label>
					<caption>
						<title>Comparación de granulometría de agregado de 16 mm con las correspondientes a tamaños de 12,7 mm y 19 mm especificadas en ASTM C33 (2018).</title>
					</caption>
					<graphic xlink:href="2215-3705-infraestructura-13-01-13-gf1.png"/>
				</fig>
			</p>
			<p>Se tiene entonces que, si bien las fuentes proveedoras comercializan el agregado como de 16 mm, sus límites granulométricos se asemejan al de 12,7 mm para el agregado de tajo y al de 19 mm para el agregado de río.</p>
			<p>Por su parte, <xref ref-type="bibr" rid="B18">Delgado (2018</xref>), realizó un estudio similar al de <xref ref-type="bibr" rid="B19">Hernández (2018</xref>) utilizando también el cemento como “variable de estudio”; en este caso los cementos fueron MM/A (E-C) - 28, MM/B (P-C) - 28 y MP A - AR, y al igual que en el estudio de Hernández (2018) usó agregado de 16 mm proveniente de río y de tajo. Delgado (2018) comparó la granulometría de este agregado con las correspondientes a los tamaños máximos nominales de 19 mm a 9.5 mm, 19 mm a 4.75 mm y 12.7 mm a 4.75 mm, encontrando que, para el agregado de río, la mejor aproximación se lograba con la segunda (19 mm a 4.75 mm), mientras que para el agregado de tajo la serie que mejor ajustaba era la tercera (12.7 mm a 4.75 mm), constatando así los resultados que obtuvo Hernández. En la <xref ref-type="fig" rid="f2">Figura 2</xref> se presentan los resultados obtenidos por Delgado (2018). </p>
			<p>
				<fig id="f2">
					<label>Figura 2</label>
					<caption>
						<title>Comparación de granulometría de agregado de 16 mm con las correspondientes a tamaños de 12,7 mm y 19 mm especificadas en ASTM C33 (2018).</title>
					</caption>
					<graphic xlink:href="2215-3705-infraestructura-13-01-13-gf2.png"/>
				</fig>
			</p>
			<p>Si bien los trabajos desarrollados por <xref ref-type="bibr" rid="B18">Delgado (2018</xref>) y <xref ref-type="bibr" rid="B19">Hernández (2018</xref>), permitieron concluir que, para las fuentes de agregados de dónde provino el material para sus estudios, sus granulometrías se podían comparar con las de 12,7 mm (agregado de tajo) y la de 19 mm (agregado de río) contenidas en la ASTM C33 (2018), ambos recomendaron que, si en el país se comercializa agregado grueso de 16 mm, es conveniente establecer un “estándar granulométrico” para este tamaño de agregado que se produce a nivel local, pues “si bien se obtuvo que el agregado cumple con las especificaciones para otros tamaños nominales en la norma ASTM C33 (2018), finalmente se trata de un agregado al cual no se le puede realizar una verificación directa de este parámetro, y tal como se obtuvo con el trabajo, la distribución de tamaño de sus partículas puede variar considerablemente de una fuente a otra.” (Delgado, 2018, p. 149)</p>
		</sec>
		<sec>
			<title>Objetivos</title>
			<p>Por lo tanto, el estudio cuyos resultados se presentan en este artículo se centró en: </p>
			<p>Comprobar, a partir de un muestreo estadísticamente válido, si la granulometría correspondiente a un tamaño máximo nominal de 19 mm según ASTM C33 (2018), es apta cuando se emplea agregado de río con un tamaño máximo nominal de 16 mm.</p>
			<p>Comprobar, a partir de un muestreo estadísticamente válido, si la granulometría correspondiente a un tamaño máximo nominal de 12,7 mm según ASTM C33 (2018), es apta cuando se emplea agregado de tajo con un tamaño máximo nominal de 16 mm.</p>
			<p>Generar una propuesta de límites granulométricos para agregados nacionales con tamaño máximo nominal de 16 mm.</p>
		</sec>
		<sec sec-type="methods">
			<title>Metodología</title>
			<p>Los ensayos en laboratorio se realizaron en el Laboratorio Nacional de Materiales y Modelos Estructurales (LanammeUCR). En la <xref ref-type="table" rid="t1">Tabla 1</xref> se indican las normas de referencia utilizadas para cada uno de los ensayos: </p>
			<p>
				<table-wrap id="t1">
					<label>Tabla 1. </label>
					<caption>
						<title>Normas de referencia utilizadas para cada uno de los ensayos</title>
					</caption>
					<graphic xlink:href="2215-3705-infraestructura-13-01-13-gt1.png"/>
				</table-wrap>
			</p>
			<p>En todos los ensayos se empleó el mismo agregado fino (agregado de tajo) y el mismo tipo de cemento (MM/C (C-P)-28), y agua potable; y se tomaron las medidas para que todos estos materiales se mantuvieran invariables, teniendo así, como única variable, los agregados objeto de estudio.</p>
			<p>En primer término, se seleccionaron ocho muestras de agregado fino a las cuales se les realizó el análisis granulométrico siguiendo la norma <xref ref-type="bibr" rid="B15">ASTM C136 (2019)</xref>, y se obtuvo la desviación entre muestras. A continuación, se determinó para cuatro muestras, su densidad relativa y absorción según <xref ref-type="bibr" rid="B3">ASTM C128 (2015)</xref>, y para dos de las muestras, su peso unitario según <xref ref-type="bibr" rid="B11">ASTM C29 (2017)</xref> e impurezas orgánicas según <xref ref-type="bibr" rid="B17">ASTM C40 (2020)</xref>. </p>
			<p>Se continuó con la granulometría del agregado grueso, para lo cual se efectuaron 30 ensayos granulométricos por fuente (una de río y una de tajo). Con las granulometrías obtenidas se determinó la desviación estándar entre muestras para cada tamiz. Una vez hecha esta caracterización, con base en cuatro muestras se determinó la densidad relativa y absorción según ASTM C128 (2015), el peso unitario para dos muestras según ASTM C29 (2017), y abrasión en máquina Los Ángeles para tres muestras. Las muestras se tomaron del lote almacenado según los establecido en la norma <xref ref-type="bibr" rid="B2">ASTM D75 (2014) </xref>y se almacenaron en baldes debidamente sellados y numerados; posteriormente, se redujeron siguiendo la norma <xref ref-type="bibr" rid="B13">ASTM C702 (2018)</xref>. Cada muestra se tomó alternadamente de cada balde.</p>
			<p>En cuanto al cemento, este se muestreó de acuerdo con lo que establece la norma <xref ref-type="bibr" rid="B6">ASTM C183 (2016)</xref>. Las muestras fueron tomadas al azar del lote de sacos de cemento destinado para la elaboración de los especímenes de concreto. Para cada ensayo se tomaron dos muestras.</p>
			<p>En el ensayo de resistencia a compresión de cubos de mortero según <xref ref-type="bibr" rid="B5">ASTM C109 (2016)</xref>, por cada muestra se elaboraron 9 cubos (3 cubos por cada edad de falla), y se fallaron a las mismas edades de los cilindros de concreto (3 días, 7 días y 28 días). Los cubos se sumergieron en agua con cal en un recipiente ubicado en la cámara húmeda hasta la edad de falla respectiva.</p>
			<p>Una vez obtenidas las características de los agregados y el cemento, se realizó el diseño de mezcla según el método especificado en <xref ref-type="bibr" rid="B1">(ACI 211.1, 2002) </xref>La relación agua cemento se mantuvo en 0.56, la resistencia de diseño se especificó en 24 MPa más un factor de seguridad de 4 MPa, y no se emplearon aditivos.</p>
			<p>Luego de obtener las dosificaciones, se elaboraron tres cilindros por edad de prueba (3 días, 7 días y 28 días), y una viga, por fuente (río o tajo). Esto para verificar el cumplimiento del asentamiento especificado y realizar los ensayos de fabricación de especímenes de concreto en laboratorio según <xref ref-type="bibr" rid="B7">ASTM C192 (2016)</xref>, asentamiento según <xref ref-type="bibr" rid="B4">ASTM C143 (2015)</xref> y temperatura del concreto <xref ref-type="bibr" rid="B8">ASTM C1064 (2017)</xref>.</p>
			<p>De seguido, se elaboraron 30 cilindros de concreto de 150 mm x 300 mm, por cada fuente. Para cada una de las mezclas se realizó la prueba de asentamiento según ASTM C143 (2015) para monitorear la consistencia de la muestra de concreto fresco, así como la determinación de la temperatura. En adición, se elaboraron tres vigas por cada fuente para la resistencia de diseño (24 MPa) para obtener módulos de ruptura, para lo cual se siguió el método de ensayo descrito en la norma <xref ref-type="bibr" rid="B14">ASTM C78 (2018)</xref>, que cubre la determinación del esfuerzo de flexión del concreto utilizando una viga simple con carga en los tercios medios; los resultados obtenidos se calcularon y se reportaron como el módulo de ruptura ( f r ).</p>
			<p>Para la elaboración de los especímenes de concreto, se dividió la muestra total en dos poblaciones, para fabricar 15 cilindros por batida. En la primera batida, además de los 15 cilindros, se elaboraron las 3 vigas, y en la segunda batida se realizó la prueba de contenido de aire según <xref ref-type="bibr" rid="B10">ASTM C231 (2017)</xref> y la densidad del concreto fresco según <xref ref-type="bibr" rid="B9">ASTM C138 (2017)</xref>. Este procedimiento se hizo para los agregados de ambas fuentes (río y tajo).</p>
			<p>Para el curado de los especímenes de prueba, estos se mantuvieron en cámara húmeda bajo condiciones ambientales controladas y se fallaron según <xref ref-type="bibr" rid="B16">ASTM C39 (2020)</xref> a edades de 3 días, 7 días y 28 días (se fallaron 10 cilindros por edad de prueba, para un total de 30 cilindros para la resistencia de diseño). </p>
			<p>Para un mayor control sobre el curado de los especímenes, se zonificó la cámara húmeda en 3 áreas de forma tal que, de los 15 cilindros que se fabricaron por batida, 5 se ubicaron en cada una de estas zonas. Al momento de la falla, se seleccionaron 2 cilindros de la zona 1, dos cilindros de la zona 2, y un cilindro de la zona 3. Antes de fallar los cilindros, se pulieron las superficies para cumplir perpendicularidad y planicidad y se tomaron las medidas para calcular el área promedio de la parte transversal del espécimen de ensayo (dos diámetros y tres alturas).</p>
			<p>Los datos recolectados se procesaron utilizando hojas electrónicas creadas en el programa Microsoft Excel. El análisis estadístico se hizo utilizando el software R con el fin de mostrar la significancia de los resultados obtenidos. Estas pruebas incluyen medidas de tendencia central y variabilidad, pruebas de normalidad, pruebas de valor extremo y pruebas de hipótesis. Además, los gráficos de las curvas granulométricas también se realizaron con el software R.</p>
		</sec>
		<sec sec-type="results|discussion">
			<title>Resultados y discusión</title>
			<sec>
				<title>Agregado fino</title>
				<p>En la <xref ref-type="table" rid="t2">Tabla 2</xref> y en la <xref ref-type="fig" rid="f3">Figura 3</xref> se muestran los resultados obtenidos para el agregado fino proveniente de río que se utilizó en todas las mezclas de concreto que se elaboraron (siempre el mismo). La curva granulométrica de la figura 3 corresponde al promedio de 8 ensayos granulométricos, y se hace notar que hubo muy poca variabilidad entre muestras. </p>
				<p>
					<table-wrap id="t2">
						<label>Tabla 2</label>
						<caption>
							<title>Resumen de las propiedades físicas del agregado fino de río</title>
						</caption>
						<table>
							<colgroup>
								<col/>
								<col/>
								<col/>
							</colgroup>
							<thead>
								<tr>
									<th align="center">Propiedad física</th>
									<th align="center">Valor promedio</th>
									<th align="center">Valor usual</th>
								</tr>
							</thead>
							<tbody>
								<tr>
									<td align="center">Módulo de finura (M.F.)</td>
									<td align="center">2,72</td>
									<td align="center">2,3 - 3,1</td>
								</tr>
								<tr>
									<td align="center">Material lavado pasando la No.200 (%)</td>
									<td align="center">4,6</td>
									<td align="center">&gt; 5</td>
								</tr>
								<tr>
									<td align="center">Gravedad específica, G<sub>BS</sub></td>
									<td align="center">2,52</td>
									<td align="center">2,4 - 2,9</td>
								</tr>
								<tr>
									<td align="center">Densidad, D<sub>BS</sub> (kg/m<sup>3</sup>)</td>
									<td align="center">2516</td>
									<td align="center">2400 - 2900</td>
								</tr>
								<tr>
									<td align="center">Absorción, D (%)</td>
									<td align="center">3,2</td>
									<td align="center">0,2 - 2</td>
								</tr>
								<tr>
									<td align="center">Peso unitario suelto, δ<sub>suelto</sub> (kg/m<sup>3</sup>)</td>
									<td align="center">1517</td>
									<td align="center">1120 - 1900</td>
								</tr>
								<tr>
									<td align="center">Peso unitario varillado, δ<sub>varillado</sub> (kg/m<sup>3</sup>)</td>
									<td align="center">1641</td>
									<td align="center">1120 - 1900</td>
								</tr>
								<tr>
									<td align="center">Relación de vacíos, e (%)</td>
									<td align="center">40</td>
									<td align="center">40 - 50</td>
								</tr>
								<tr>
									<td align="center">Porosidad, n</td>
									<td align="center">0,28</td>
									<td align="center">0,29 - 0,33</td>
								</tr>
								<tr>
									<td align="center">Impurezas orgánicas</td>
									<td align="center">Conforme</td>
									<td align="center">Solución más clara que el vidrio color estándar de Gardner No.3</td>
								</tr>
								<tr>
									<td align="center">Humedad, W<sub>lab</sub> (%)</td>
									<td align="center">2,9</td>
									<td align="center">0,2 - 2</td>
								</tr>
							</tbody>
						</table>
					</table-wrap>
				</p>
				<p>
					<fig id="f3">
						<label>Figura 3</label>
						<caption>
							<title>Curva granulométrica del agregado fino (promedio de ocho muestras) </title>
						</caption>
						<graphic xlink:href="2215-3705-infraestructura-13-01-13-gf3.png"/>
					</fig>
				</p>
			</sec>
			<sec>
				<title>Cemento</title>
				<p>Como se indicó anteriormente, el cemento utilizado fue el MM/C (C-P)-28. Los resultados de los ensayos para este cemento se presentan en la <xref ref-type="table" rid="t3">Tabla 3</xref> y en la <xref ref-type="fig" rid="f4">Figura 4</xref>.</p>
				<p>
					<table-wrap id="t3">
						<label>Tabla 3</label>
						<caption>
							<title>Resultados de las propiedades físicas del cemento MM/C (C-P)-28 utilizado</title>
						</caption>
						<table>
							<colgroup>
								<col/>
								<col/>
								<col/>
							</colgroup>
							<thead>
								<tr>
									<th align="center">Propiedad</th>
									<th align="center">Valor promedio</th>
									<th align="center">Valor usual</th>
								</tr>
							</thead>
							<tbody>
								<tr>
									<td align="center">Agua para consistencia normal (%)</td>
									<td align="center">30</td>
									<td align="center">27 - 30</td>
								</tr>
								<tr>
									<td align="center">Densidad relativa</td>
									<td align="center">2,81</td>
									<td align="center">2,8 - 2,85</td>
								</tr>
								<tr>
									<td align="center">Tiempo de fragua inicial (min)</td>
									<td align="center">111</td>
									<td align="center">90</td>
								</tr>
								<tr>
									<td align="center">Tiempo de fragua final (min)</td>
									<td align="center">264</td>
									<td align="center">240</td>
								</tr>
								<tr>
									<td align="center">Finura por material pasando tamiz de 45 µm (%)</td>
									<td align="center">94,8</td>
									<td align="center">94</td>
								</tr>
							</tbody>
						</table>
					</table-wrap>
				</p>
				<p>
					<fig id="f4">
						<label>Figura 4</label>
						<caption>
							<title>Curva de desarrollo de resistencia en cubos de mortero de cemento MM/C (C-P)-28 (promedio de dos réplicas de 9 cubos cada una)</title>
						</caption>
						<graphic xlink:href="2215-3705-infraestructura-13-01-13-gf4.png"/>
					</fig>
				</p>
				<p>Para obtener los resultados promedio, se verificó que el rango máximo permisible entre especímenes hechos de una misma mezcla de mortero y a la misma edad, es de 8.7 % del promedio cuando tres cubos representan la edad de ensayo, y de 7.6 % cuando dos cubos representan la edad de ensayo.</p>
			</sec>
			<sec>
				<title>Agregado grueso</title>
				<p>El agregado grueso constituyó la variable en este estudio. Se realizaron 30 ensayos granulométricos para el agregado de tajo y otros 30 para el agregado de río y se obtuvo, para cada caso, el promedio que se presenta en la <xref ref-type="table" rid="t4">Tabla 4</xref> y en la <xref ref-type="table" rid="t5">Tabla 5</xref>.</p>
				<p>
					<table-wrap id="t4">
						<label>Tabla 4</label>
						<caption>
							<title>Granulometría del agregado grueso de río (promedio de 30 muestras)</title>
						</caption>
						<table>
							<colgroup>
								<col/>
								<col/>
								<col/>
								<col/>
								<col/>
								<col/>
							</colgroup>
							<thead>
								<tr>
									<th align="center">Tamiz</th>
									<th align="center">Tamaño (mm)</th>
									<th align="center">Porcentaje retenido</th>
									<th align="center">Porcentaje retenido acumulado</th>
									<th align="center">Porcentaje pasando</th>
									<th align="center">Desviación estándar (%)</th>
								</tr>
							</thead>
							<tbody>
								<tr>
									<td align="center">3/4''</td>
									<td align="center">19</td>
									<td align="center">0,0</td>
									<td align="center">0,0</td>
									<td align="center">100</td>
									<td align="center">0,0</td>
								</tr>
								<tr>
									<td align="center">1/2''</td>
									<td align="center">12,7</td>
									<td align="center">23,7</td>
									<td align="center">23,7</td>
									<td align="center">76,3</td>
									<td align="center">2,2</td>
								</tr>
								<tr>
									<td align="center">3/8''</td>
									<td align="center">9,5</td>
									<td align="center">52,7</td>
									<td align="center">76,3</td>
									<td align="center">23,7</td>
									<td align="center">2,1</td>
								</tr>
								<tr>
									<td align="center">No.4</td>
									<td align="center">4,75</td>
									<td align="center">23,4</td>
									<td align="center">99,7</td>
									<td align="center">0,3</td>
									<td align="center">2,6</td>
								</tr>
								<tr>
									<td align="center">No.8</td>
									<td align="center">2,36</td>
									<td align="center">0,0</td>
									<td align="center">99,7</td>
									<td align="center">0,3</td>
									<td align="center">0,0</td>
								</tr>
								<tr>
									<td align="center">No.16</td>
									<td align="center">1,18</td>
									<td align="center">0,0</td>
									<td align="center">99,7</td>
									<td align="center">0,3</td>
									<td align="center">0,0</td>
								</tr>
								<tr>
									<td align="center">No.30</td>
									<td align="center">0,60</td>
									<td align="center">0,0</td>
									<td align="center">99,8</td>
									<td align="center">0,2</td>
									<td align="center">0,0</td>
								</tr>
								<tr>
									<td align="center">No.50</td>
									<td align="center">0,30</td>
									<td align="center">0,0</td>
									<td align="center">99,8</td>
									<td align="center">0,2</td>
									<td align="center">0,0</td>
								</tr>
								<tr>
									<td align="center">No.100</td>
									<td align="center">0,15</td>
									<td align="center">0,0</td>
									<td align="center">99,8</td>
									<td align="center">0,2</td>
									<td align="center">0,0</td>
								</tr>
								<tr>
									<td align="center">No.200</td>
									<td align="center">0,075</td>
									<td align="center">0,0</td>
									<td align="center">99,8</td>
									<td align="center">0,2</td>
									<td align="center">0,0</td>
								</tr>
								<tr>
									<td align="center">Charola</td>
									<td align="center">N/A</td>
									<td align="center">0,1</td>
									<td align="center">99,9</td>
									<td align="center">0,1</td>
									<td align="center">0,0</td>
								</tr>
								<tr>
									<td align="center">Promedio de material lavado pasando la No.200</td>
									<td align="center">Promedio de material lavado pasando la No.200</td>
									<td align="center">0,1</td>
									<td align="center">-</td>
									<td align="center">-</td>
									<td align="center">0,04</td>
								</tr>
							</tbody>
						</table>
					</table-wrap>
				</p>
				<p>
					<table-wrap id="t5">
						<label>Tabla 5</label>
						<caption>
							<title>Granulometría del agregado grueso de tajo (promedio de 30 muestras)</title>
						</caption>
						<table>
							<colgroup>
								<col/>
								<col/>
								<col/>
								<col/>
								<col/>
								<col/>
							</colgroup>
							<thead>
								<tr>
									<th align="center">Tamiz</th>
									<th align="center">Tamaño (mm)</th>
									<th align="center">Porcentaje retenido</th>
									<th align="center">Porcentaje retenido acumulado</th>
									<th align="center">Porcentaje pasando</th>
									<th align="center">Desviación estándar (%)</th>
								</tr>
							</thead>
							<tbody>
								<tr>
									<td align="center">3/4''</td>
									<td align="center">19</td>
									<td align="center">0,0</td>
									<td align="center">0,0</td>
									<td align="center">100</td>
									<td align="center">0,0</td>
								</tr>
								<tr>
									<td align="center">1/2''</td>
									<td align="center">12,7</td>
									<td align="center">10,3</td>
									<td align="center">10,3</td>
									<td align="center">89,7</td>
									<td align="center">2,0</td>
								</tr>
								<tr>
									<td align="center">3/8''</td>
									<td align="center">9,50</td>
									<td align="center">32,9</td>
									<td align="center">43,2</td>
									<td align="center">56,8</td>
									<td align="center">4,1</td>
								</tr>
								<tr>
									<td align="center">No.4</td>
									<td align="center">4,75</td>
									<td align="center">49,3</td>
									<td align="center">92,5</td>
									<td align="center">7,5</td>
									<td align="center">1,7</td>
								</tr>
								<tr>
									<td align="center">No.8</td>
									<td align="center">2,36</td>
									<td align="center">6,8</td>
									<td align="center">99,5</td>
									<td align="center">0,5</td>
									<td align="center">0,1</td>
								</tr>
								<tr>
									<td align="center">No.16</td>
									<td align="center">1,18</td>
									<td align="center">0,2</td>
									<td align="center">99,7</td>
									<td align="center">0,3</td>
									<td align="center">0,1</td>
								</tr>
								<tr>
									<td align="center">No.30</td>
									<td align="center">0,60</td>
									<td align="center">0,0</td>
									<td align="center">99,7</td>
									<td align="center">0,3</td>
									<td align="center">0,1</td>
								</tr>
								<tr>
									<td align="center">No.50</td>
									<td align="center">0,30</td>
									<td align="center">0,0</td>
									<td align="center">99,7</td>
									<td align="center">0,3</td>
									<td align="center">0,1</td>
								</tr>
								<tr>
									<td align="center">No.100</td>
									<td align="center">0,15</td>
									<td align="center">0,0</td>
									<td align="center">99,7</td>
									<td align="center">0,3</td>
									<td align="center">0,1</td>
								</tr>
								<tr>
									<td align="center">No.200</td>
									<td align="center">0,075</td>
									<td align="center">0,0</td>
									<td align="center">99,8</td>
									<td align="center">0,2</td>
									<td align="center">0,1</td>
								</tr>
								<tr>
									<td align="center">Charola</td>
									<td align="center">N/A</td>
									<td align="center">0,0</td>
									<td align="center">99,8</td>
									<td align="center">0,2</td>
									<td align="center">0,1</td>
								</tr>
								<tr>
									<td align="center">Promedio de material lavado pasando la No.200</td>
									<td align="center">Promedio de material lavado pasando la No.200</td>
									<td align="center">0.3</td>
									<td align="center">-</td>
									<td align="center">-</td>
									<td align="center">0,14</td>
								</tr>
							</tbody>
						</table>
					</table-wrap>
				</p>
				<p>Es importante indicar que, antes de definir una granulometría promedio, primero se realizó un análisis estadístico de los datos para determinar su distribución y verificar si estos cumplían con una distribución normal, como también para detectar valores extremos que afectaran el cumplimiento de la distribución normal de los datos. A partir de estas granulometrías promedio se procedió con el resto de los ensayos, cuyos resultados se muestran en la <xref ref-type="table" rid="t6">Tabla 6</xref>.</p>
				<p>
					<table-wrap id="t6">
						<label>Tabla 6</label>
						<caption>
							<title>Resumen de las propiedades físicas de los agregados gruesos utilizados</title>
						</caption>
						<table>
							<colgroup>
								<col/>
								<col/>
								<col/>
								<col/>
							</colgroup>
							<thead>
								<tr>
									<th align="center">Propiedad física</th>
									<th align="center">Valor promedio</th>
									<th align="center">Valor promedio</th>
									<th align="center">Valor usual</th>
								</tr>
							</thead>
							<tbody>
								<tr>
									<td align="center">-</td>
									<td align="center">Río</td>
									<td align="center">Tajo</td>
									<td align="center">-</td>
								</tr>
								<tr>
									<td align="center">Tamaño máximo (mm)</td>
									<td align="center">16</td>
									<td align="center">16</td>
									<td align="center">-</td>
								</tr>
								<tr>
									<td align="center">Material lavado pasando la No.200 (%)</td>
									<td align="center">0,1</td>
									<td align="center">0,3</td>
									<td align="center">1</td>
								</tr>
								<tr>
									<td align="center">Gravedad específica, G<sub>BS</sub></td>
									<td align="center">2,64</td>
									<td align="center">2,51</td>
									<td align="center">2,4 - 2,8</td>
								</tr>
								<tr>
									<td align="center">Densidad, D<sub>BS</sub> (kg/m<sup>3</sup>)</td>
									<td align="center">2630</td>
									<td align="center">2509</td>
									<td align="center">2400 - 2900</td>
								</tr>
								<tr>
									<td align="center">Absorción, D (%)</td>
									<td align="center">1,8</td>
									<td align="center">2</td>
									<td align="center">0,2 - 4</td>
								</tr>
								<tr>
									<td align="center">Peso unitario suelto, δ<sub>suelto</sub> (kg/m<sup>3</sup>)</td>
									<td align="center">1408</td>
									<td align="center">1402</td>
									<td align="center" rowspan="2">1120 - 1900</td>
								</tr>
								<tr>
									<td align="center">Peso unitario varillado, δ<sub>varillado</sub> (kg/m<sup>3</sup>)</td>
									<td align="center">1539</td>
									<td align="center">1485</td>
								</tr>
								<tr>
									<td align="center">Relación de vacíos, e (%)</td>
									<td align="center">47</td>
									<td align="center">44</td>
									<td align="center">30 - 45</td>
								</tr>
								<tr>
									<td align="center">Porosidad, n</td>
									<td align="center">0,32</td>
									<td align="center">0,31</td>
									<td align="center">0,23 - 0,31</td>
								</tr>
								<tr>
									<td align="center">Pérdida por abrasión (%)</td>
									<td align="center">18</td>
									<td align="center">16</td>
									<td align="center">&gt; 50</td>
								</tr>
								<tr>
									<td align="center">Partículas fracturadas (%)</td>
									<td align="center">95</td>
									<td align="center">100</td>
									<td align="center">-</td>
								</tr>
								<tr>
									<td align="center">Humedad, W<sub>lab</sub> (%)</td>
									<td align="center">0,9</td>
									<td align="center">0,7</td>
									<td align="center">0,5 - 2</td>
								</tr>
							</tbody>
						</table>
					</table-wrap>
				</p>
				<p>Para el análisis estadístico de los datos se utilizaron las pruebas de normalidad de Jarque-Bera y Anderson-Darling para determinar si los resultados cumplían o no con una distribución normal. Cuando no cumplieron normalidad, se realizaron dos pruebas para comprobar la presencia de valores atípicos (Test de Dixon y Test de Grubbs), y eliminar el valor atípico. Posteriormente, se volvieron a realizar las pruebas de normalidad para verificar su cumplimiento. Por último, se realizó la prueba z o la prueba t de Student, según el tamaño de la muestra, para establecer si los resultados entre ambas fuentes son estadísticamente iguales o no y obtener el intervalo de confianza con un 95 %. Como el análisis estadístico se hizo para cada tamaño de tamiz, se obtuvo que, los tamaños de 12,7 mm (1/2”) y 9,5 mm (3/8”), tanto para el agregado de tajo como para el de río, cumplieron con la distribución normal, pero a partir del tamiz de 4,75 mm (No.4), se observa que los datos correspondientes al agregado de tajo no cumplen normalidad en al menos una de las pruebas realizadas.</p>
				<p>Una vez que se verificó que todos los datos cumplían con una distribución normal, se continuó con la prueba de hipótesis para determinar, con base en el porcentaje pasando, si las poblaciones estudiadas son estadísticamente iguales o no. Para esto se realizó la prueba z en caso de tener 30 o más observaciones (N), o la prueba t de Student si eran menos de 30 observaciones.</p>
				<p>En el caso del agregado de río todos los datos granulométricos cumplieron con la distribución normal, pero para el agregado de tajo fue necesario eliminar valores atípicos para cumplir con la normalidad en la mayoría de los tamices.</p>
				<p>En la <xref ref-type="fig" rid="f5">Figura 5</xref> se pueden observar las 30 curvas granulométricas del agregado grueso de río (color verde) y las 30 curvas granulométricas del agregado grueso de tajo (color gris tenue). Además, en un color más oscuro (verde oscuro y gris oscuro) se distinguen los intervalos con un 95 % de confianza para cada caso.</p>
				<p>
					<fig id="f5">
						<label>Figura 5</label>
						<caption>
							<title>Curvas granulométricas de agregado grueso de tajo y río, e intervalos con un 95 % de confianza.</title>
						</caption>
						<graphic xlink:href="2215-3705-infraestructura-13-01-13-gf5.jpg"/>
					</fig>
				</p>
				<p>Los registros históricos proporcionados por los proveedores, correspondientes a diferentes años, permitieron comparar la tendencia granulométrica histórica del agregado grueso de 16 mm con la obtenida en los ensayos de laboratorio que se realizaron como parte de este estudio. Con base en esta información se determinó que, para el agregado de tajo hay muy poca variación en la mayoría de los tamices, y solo el de 9,5 mm (3/8”) presentaba una mayor variación (7,2 %). Para el agregado grueso de río las variaciones son incluso menores que las reportadas para el de tajo, pero se destaca que es también el tamiz de 9,5 mm (3/8”) el que reporta la mayor variación (5,4 %). En la <xref ref-type="fig" rid="f6">figura 6</xref> se muestran las curvas granulométricas promedio del agregado grueso de río (color verde) y el agregado grueso de tajo (color gris) trazadas con base en los registros históricos. </p>
				<p>
					<fig id="f6">
						<label>Figura 6</label>
						<caption>
							<title>Curvas granulométricas construidas a partir de datos históricos suministrados por las fuentes de agregados.</title>
						</caption>
						<graphic xlink:href="2215-3705-infraestructura-13-01-13-gf6.png"/>
					</fig>
				</p>
				<p>A continuación, en la <xref ref-type="fig" rid="f7">Figura 7</xref> se puede observar el comparativo de curvas granulométricas obtenidas en este trabajo y las incluidas en la <xref ref-type="fig" rid="f6">Figura 6</xref>.</p>
				<p>
					<fig id="f7">
						<label>Figura 7</label>
						<caption>
							<title>Curvas granulométricas promedio del agregado grueso de río y agregado grueso de tajo, resultantes de los registros históricos de los quebradores y los resultados obtenidos en este trabajo.</title>
						</caption>
						<graphic xlink:href="2215-3705-infraestructura-13-01-13-gf7.png"/>
					</fig>
				</p>
				<p>Con base en el análisis estadístico de los resultados de los ensayos de granulometría y, considerando también, el comportamiento granulométrico de estos agregados atendiendo a los registros históricos de los ensayos proporcionados por los quebradores, se definió una propuesta de límites granulométricos para un agregado con tamaño máximo nominal de 16 mm que se observa en la <xref ref-type="table" rid="t7">Tabla 7</xref>.</p>
				<p>
					<table-wrap id="t7">
						<label>Tabla 7. </label>
						<caption>
							<title>Límites granulométricos inferior y superior propuestos para agregado de 16 mm.</title>
						</caption>
						<table>
							<colgroup>
								<col/>
								<col/>
								<col/>
								<col/>
							</colgroup>
							<thead>
								<tr>
									<th align="center">Tamiz</th>
									<th align="center">Tamaño (mm)</th>
									<th align="center">Porcentaje pasando (%)</th>
									<th align="center">Porcentaje pasando (%)</th>
								</tr>
								<tr>
									<th align="center">-</th>
									<th align="center">-</th>
									<th align="center">Límite superior </th>
									<th align="center">Límite inferior</th>
								</tr>
							</thead>
							<tbody>
								<tr>
									<td align="center">3/5''</td>
									<td align="center">16.0</td>
									<td align="center">100</td>
									<td align="center">100</td>
								</tr>
								<tr>
									<td align="center">1/2''</td>
									<td align="center">12,7</td>
									<td align="center">100</td>
									<td align="center">70</td>
								</tr>
								<tr>
									<td align="center">3/8''</td>
									<td align="center">9,5</td>
									<td align="center">65</td>
									<td align="center">20</td>
								</tr>
								<tr>
									<td align="center">No.4</td>
									<td align="center">4,75</td>
									<td align="center">10</td>
									<td align="center">0</td>
								</tr>
								<tr>
									<td align="center">No.8</td>
									<td align="center">2,36</td>
									<td align="center">2</td>
									<td align="center">0</td>
								</tr>
								<tr>
									<td align="center">No.16</td>
									<td align="center">1,18</td>
									<td align="center">0</td>
									<td align="center">0</td>
								</tr>
								<tr>
									<td align="center">No.30</td>
									<td align="center">0,60</td>
									<td align="center">0</td>
									<td align="center">0</td>
								</tr>
								<tr>
									<td align="center">No.50</td>
									<td align="center">0,30</td>
									<td align="center">0</td>
									<td align="center">0</td>
								</tr>
								<tr>
									<td align="center">No.100</td>
									<td align="center">0,15</td>
									<td align="center">0</td>
									<td align="center">0</td>
								</tr>
								<tr>
									<td align="center">No.200</td>
									<td align="center">0,075</td>
									<td align="center">0</td>
									<td align="center">0</td>
								</tr>
							</tbody>
						</table>
					</table-wrap>
				</p>
				<p>De acuerdo con la ASTM C33 (2018), para un tamaño máximo nominal de 12,7 mm, se admite en ese tamiz un sobre tamaño de 10 % de la masa seca al horno; en esta propuesta, pasa el 100 % en el tamiz de 16 mm pero se puede retener hasta un 30 % en el tamiz de 12,7 mm</p>
			</sec>
			<sec>
				<title>Concreto hidráulico</title>
				<p>Con base en la granulometría propuesta se elaboraron dos diseños de mezcla atendiendo al procedimiento establecido por la (ACI 211.1, 2002) Método estándar para el proporcionamiento de mezclas de concreto de peso liviano, normal y masivo.; en un caso se utilizó agregado de río y en otro agregado de tajo, respetando en ambos casos la granulometría propuesta en este trabajo. El resto de los factores que intervienen en el diseño se mantuvieron constantes, no obstante, se hace la salvedad que, debido a la capacidad de la batidora, para satisfacer la cantidad de mezcla para elaborar 30 cilindros, se hicieron dos baches de 15 cilindros para mezclas con agregado de tajo y otros dos baches para mezclas con agregado de río, y se llevó control de los parámetros indicados en la <xref ref-type="table" rid="t8">Tabla 8</xref>.</p>
				<p>
					<table-wrap id="t8">
						<label>Tabla 8</label>
						<caption>
							<title>Parámetros de control de las mezclas de concreto en cada bache producido.</title>
						</caption>
						<table>
							<colgroup>
								<col/>
								<col/>
								<col/>
								<col/>
								<col/>
							</colgroup>
							<thead>
								<tr>
									<th align="center">-</th>
									<th align="center">Mezcla de concreto con agregado de río</th>
									<th align="center">Mezcla de concreto con agregado de río</th>
									<th align="center">Mezcla de concreto con agregado de tajo</th>
									<th align="center">Mezcla de concreto con agregado de tajo</th>
								</tr>
								<tr>
									<th align="center">Parámetro</th>
									<th align="center">Valor obtenido</th>
									<th align="center">Valor obtenido</th>
									<th align="center">Valor obtenido</th>
									<th align="center">Valor obtenido</th>
								</tr>
								<tr>
									<th align="center">-</th>
									<th align="center">Bache 1</th>
									<th align="center">Bache 2</th>
									<th align="center">Bache 1</th>
									<th align="center">Bache 2</th>
								</tr>
							</thead>
							<tbody>
								<tr>
									<td align="center">Temperatura de la mezcla (°C)</td>
									<td align="center">26,2</td>
									<td align="center">27,3</td>
									<td align="center">27,1</td>
									<td align="center">26,0</td>
								</tr>
								<tr>
									<td align="center">Asentamiento (mm)</td>
									<td align="center">150</td>
									<td align="center">180</td>
									<td align="center">190</td>
									<td align="center">180</td>
								</tr>
								<tr>
									<td align="center">Contenido de aire (%)</td>
									<td align="center">-</td>
									<td align="center">1,4</td>
									<td align="center">-</td>
									<td align="center">1,3</td>
								</tr>
								<tr>
									<td align="center">Densidad del concreto fresco (kg/m3)</td>
									<td align="center">-</td>
									<td align="center">2278,4</td>
									<td align="center">-</td>
									<td align="center">2230,4</td>
								</tr>
								<tr>
									<td align="center">Relación agua cemento (a/c)</td>
									<td align="center">0,56</td>
									<td align="center">0,56</td>
									<td align="center">0,56</td>
									<td align="center">0,56</td>
								</tr>
							</tbody>
						</table>
					</table-wrap>
				</p>
				<p>En la <xref ref-type="fig" rid="f8">Figura 8</xref> se incluyen los resultados de la resistencia a compresión simple en cilindros de concreto para la mezcla con agregado de río y para la mezcla con agregado de tajo, utilizando la granulometría respectiva propuesta en este trabajo para agregado de 16 mm.</p>
				<p>
					<fig id="f8">
						<label>Figura 8</label>
						<caption>
							<title>Curvas de desarrollo de resistencia para concretos hidráulicos elaborados con la granulometría propuesta para agregado de 16 mm.</title>
						</caption>
						<graphic xlink:href="2215-3705-infraestructura-13-01-13-gf8.png"/>
					</fig>
				</p>
				<p>La resistencia de diseño fue de 24 MPa y se usó un factor de seguridad de 4 MPa, por lo que, bajo condiciones controladas en laboratorio, se alcanzaron resistencias superiores a la de diseño.</p>
				<p>Finalmente, con respecto al módulo de rotura de las vigas de concreto a 28 días, se fabricaron 3 con el agregado grueso de tajo y 3 con el agregado grueso de río, empleando la granulometría propuesta en este trabajo para el agregado de 16 mm, y el resto de los factores constante. Los resultados obtenidos están contenidos en la Tabla 9.</p>
				<p>
					<table-wrap id="t9">
						<label>Tabla 9</label>
						<caption>
							<title>Módulo de ruptura del concreto obtenido usando la granulometría propuesta para un tamaño de 16 mm</title>
						</caption>
						<table>
							<colgroup>
								<col/>
								<col/>
								<col/>
							</colgroup>
							<thead>
								<tr>
									<th align="center">Edad (días)</th>
									<th align="center">Módulo de ruptura (MPa)</th>
									<th align="center">Módulo de ruptura (MPa)</th>
								</tr>
							</thead>
							<tbody>
								<tr>
									<td align="center">-</td>
									<td align="center">Río</td>
									<td align="center">Tajo</td>
								</tr>
								<tr>
									<td align="center">28</td>
									<td align="center">3,74</td>
									<td align="center">4,31</td>
								</tr>
							</tbody>
						</table>
					</table-wrap>
				</p>
				<p>Al relacionar el módulo de ruptura con la resistencia a compresión se obtiene que, cuando se usa agregado de río en la mezcla, el módulo de ruptura a 28 días es un 10,6 % del valor de la resistencia a compresión; y al utilizar agregado de tajo, el módulo de ruptura representa un 13,6 % de la resistencia a compresión, lo que indica que en ambos casos se cumple con los valores teóricos típicos establecidos entre 10 % y 20 %. </p>
			</sec>
		</sec>
		<sec sec-type="conclusions">
			<title>Conclusiones</title>
			<p>La granulometría del agregado grueso de tajo, comercializado como de 16 mm, se asemeja a la granulometría contemplada en la norma ASTM C33 (2018), correspondiente a un tamaño máximo nominal de 12,7 mm.</p>
			<p>La granulometría del agregado grueso de río, comercializado como de 16 mm, no se asemeja ni a la granulometría para un tamaño máximo nominal de 19 mm, como tampoco, a la del tamaño de 12,7 mm, que especifica la ASTM C33 (2018).</p>
			<p>El promedio de los porcentajes pasando los tamices de 12,7 mm (1/2”), 9,5 mm (3/8”), 4,75 mm (No.4) y 2,36 mm (No.8) presentan una diferencia significativa, por lo que los resultados entre ambas fuentes de agregado (río y tajo), son distintos.</p>
			<p>En atención a los porcentajes pasando en cada tamiz, el agregado de tajo es más fino que el agregado de río, a pesar de ser comercializados con el mismo tamaño nominal, lo que evidencia la necesidad de definir una curva granulométrica (límite inferior y superior) para un tamaño máximo nominal de 16 mm.</p>
			<p>A partir de muestras estadísticamente válidas, y con un nivel de confianza de 95 %, se definió una propuesta de límites granulométricos (inferior y superior) para agregado grueso de 16 mm.</p>
			<p>La curva granulométrica histórica del agregado grueso de río se encuentra dentro de los límites granulométricos propuestos en esta investigación. Mientras que, la curva granulométrica histórica del agregado grueso de tajo se acerca considerablemente al límite superior, e incluso sobrepasa este límite en el tamiz de 4,75 mm (No.4).</p>
		</sec>
	</body>
	<back>
		<ref-list>
			<title>Referencias</title>
			<ref id="B1">
				<mixed-citation>American Concrete Institute . (2002). ACI 211.1-91 Práctica estándar para seleccionar el proporcionamiento de concreto de peso normal, pesado y masivo.</mixed-citation>
				<element-citation publication-type="book">
					<person-group person-group-type="author">
						<collab>American Concrete Institute</collab>
					</person-group>
					<year>2002</year>
					<source>ACI 211.1-91 Práctica estándar para seleccionar el proporcionamiento de concreto de peso normal, pesado y masivo</source>
				</element-citation>
			</ref>
			<ref id="B2">
				<mixed-citation>American Society for Testing and Materials. (2014). ASTM D75-14. Práctica normativa para el muestreo de agregados.</mixed-citation>
				<element-citation publication-type="book">
					<person-group person-group-type="author">
						<collab>American Society for Testing and Materials.</collab>
					</person-group>
					<year>2014</year>
					<source>ASTM D75-14. Práctica normativa para el muestreo de agregados</source>
				</element-citation>
			</ref>
			<ref id="B3">
				<mixed-citation>American Society for Testing and Materials. (2015). ASTM C128-15. Método de ensayo normalizado para determinar la densidad, la densidad relativa o gravedad específica, y la absorción de agregados finos.</mixed-citation>
				<element-citation publication-type="book">
					<person-group person-group-type="author">
						<collab>American Society for Testing and Materials.</collab>
					</person-group>
					<year>2015</year>
					<source>ASTM C128-15. Método de ensayo normalizado para determinar la densidad, la densidad relativa o gravedad específica, y la absorción de agregados finos</source>
				</element-citation>
			</ref>
			<ref id="B4">
				<mixed-citation>American Society for Testing and Materials. (2015). ASTM C143/C143M-15. Método de prueba estándar para determinar el asentamiento de concreto de cemento hidráulico. </mixed-citation>
				<element-citation publication-type="book">
					<person-group person-group-type="author">
						<collab>American Society for Testing and Materials</collab>
					</person-group>
					<year>2015</year>
					<source>ASTM C143/C143M-15. Método de prueba estándar para determinar el asentamiento de concreto de cemento hidráulico</source>
				</element-citation>
			</ref>
			<ref id="B5">
				<mixed-citation>American Society for Testing and Materials. (2016). ASTM C109-16. Método de prueba estándar para la resistencia a la compresión de morteros de cemento hidráulico.</mixed-citation>
				<element-citation publication-type="book">
					<person-group person-group-type="author">
						<collab>American Society for Testing and Materials</collab>
					</person-group>
					<year>2016</year>
					<source>ASTM C109-16. Método de prueba estándar para la resistencia a la compresión de morteros de cemento hidráulico</source>
				</element-citation>
			</ref>
			<ref id="B6">
				<mixed-citation>American Society for Testing and Materials. (2016). ASTM C183-16. Práctica normalizada para muestreo y cantidad de pruebas de cemento hidráulico.</mixed-citation>
				<element-citation publication-type="book">
					<person-group person-group-type="author">
						<collab>American Society for Testing and Materials</collab>
					</person-group>
					<year>2016</year>
					<source>ASTM C183-16. Práctica normalizada para muestreo y cantidad de pruebas de cemento hidráulico</source>
				</element-citation>
			</ref>
			<ref id="B7">
				<mixed-citation>American Society for Testing and Materials. (2016). ASTM C192-16. Práctica normalizada para preparación y curado de especímenes de concreto para ensayo en laboratorio.</mixed-citation>
				<element-citation publication-type="book">
					<person-group person-group-type="author">
						<collab>American Society for Testing and Materials.</collab>
					</person-group>
					<year>2016</year>
					<source>ASTM C192-16. Práctica normalizada para preparación y curado de especímenes de concreto para ensayo en laboratorio</source>
				</element-citation>
			</ref>
			<ref id="B8">
				<mixed-citation>American Society for Testing and Materials. (2017). ASTM C1064-17/C1064M-17. Método de prueba estándar para determinar la temperatura del concreto fresco de cemento hidráulico. </mixed-citation>
				<element-citation publication-type="book">
					<person-group person-group-type="author">
						<collab>American Society for Testing and Materials</collab>
					</person-group>
					<year>2017</year>
					<source>ASTM C1064-17/C1064M-17. Método de prueba estándar para determinar la temperatura del concreto fresco de cemento hidráulico</source>
				</element-citation>
			</ref>
			<ref id="B9">
				<mixed-citation>American Society for Testing and Materials. (2017). ASTM C138-17/C138M-17a. Método de prueba estándar para determinar la densidad (peso unitario) y rendimiento del concreto fresco.</mixed-citation>
				<element-citation publication-type="book">
					<person-group person-group-type="author">
						<collab>American Society for Testing and Materials</collab>
					</person-group>
					<year>2017</year>
					<source>ASTM C138-17/C138M-17a. Método de prueba estándar para determinar la densidad (peso unitario) y rendimiento del concreto fresco</source>
				</element-citation>
			</ref>
			<ref id="B10">
				<mixed-citation>American Society for Testing and Materials. (2017). ASTM C231-17/C231M-17a. Método de prueba estándar para determinar el contenido de aire de concretro fresco con el método de presión.</mixed-citation>
				<element-citation publication-type="book">
					<person-group person-group-type="author">
						<collab>American Society for Testing and Materials.</collab>
					</person-group>
					<year>2017</year>
					<source>ASTM C231-17/C231M-17a. Método de prueba estándar para determinar el contenido de aire de concretro fresco con el método de presión</source>
				</element-citation>
			</ref>
			<ref id="B11">
				<mixed-citation>American Society for Testing and Materials. (2017). ASTM C29/C29-17a. Método de prueba estándar para determinar la densidad masiva (“Peso unitario”) y vacíos en agregados. </mixed-citation>
				<element-citation publication-type="book">
					<person-group person-group-type="author">
						<collab>American Society for Testing and Materials.</collab>
					</person-group>
					<year>2017</year>
					<source>ASTM C29/C29-17a. Método de prueba estándar para determinar la densidad masiva (“Peso unitario”) y vacíos en agregados</source>
				</element-citation>
			</ref>
			<ref id="B12">
				<mixed-citation>American Society for Testing and Materials. (2018). ASTM C33-18/C33M-18. Especificaciones estándar para agregados para concreto.</mixed-citation>
				<element-citation publication-type="book">
					<person-group person-group-type="author">
						<collab>American Society for Testing and Materials</collab>
					</person-group>
					<year>2018</year>
					<source>ASTM C33-18/C33M-18. Especificaciones estándar para agregados para concreto</source>
				</element-citation>
			</ref>
			<ref id="B13">
				<mixed-citation>American Society for Testing and Materials. (2018). ASTM C702/C702M-18. Práctica estándar para reducir muestras de agregados a tamaño de ensayo.</mixed-citation>
				<element-citation publication-type="book">
					<person-group person-group-type="author">
						<collab>American Society for Testing and Materials</collab>
					</person-group>
					<year>2018</year>
					<source>ASTM C702/C702M-18. Práctica estándar para reducir muestras de agregados a tamaño de ensayo</source>
				</element-citation>
			</ref>
			<ref id="B14">
				<mixed-citation>American Society for Testing and Materials. (2018). ASTM C78-18/C78M-18. Método de prueba estándar para determinar la resistencia a flexión del concreto. </mixed-citation>
				<element-citation publication-type="book">
					<person-group person-group-type="author">
						<collab>American Society for Testing and Materials</collab>
					</person-group>
					<year>2018</year>
					<source>ASTM C78-18/C78M-18. Método de prueba estándar para determinar la resistencia a flexión del concreto</source>
				</element-citation>
			</ref>
			<ref id="B15">
				<mixed-citation>American Society for Testing and Materials. (2019). ASTM C136/C136M-19. Método de prueba estandar para el análisis por mallas para el agregado fino y grueso.</mixed-citation>
				<element-citation publication-type="book">
					<person-group person-group-type="author">
						<collab>American Society for Testing and Materials.</collab>
					</person-group>
					<year>2019</year>
					<source>ASTM C136/C136M-19. Método de prueba estandar para el análisis por mallas para el agregado fino y grueso</source>
				</element-citation>
			</ref>
			<ref id="B16">
				<mixed-citation>American Society for Testing and Materials. (2020). ASTM C39-20/C39M-20. Método de prueba estándar para determinar la resistencia a compresión de especímenes cilíndricos de concreto.</mixed-citation>
				<element-citation publication-type="book">
					<person-group person-group-type="author">
						<collab>American Society for Testing and Materials</collab>
					</person-group>
					<year>2020</year>
					<source>ASTM C39-20/C39M-20. Método de prueba estándar para determinar la resistencia a compresión de especímenes cilíndricos de concreto</source>
				</element-citation>
			</ref>
			<ref id="B17">
				<mixed-citation>American Society for Testing and Materials. (2020). ASTM C40/C40M-19. Método de prueba estándar para determinar impurezas orgánicas en agregado fino para concreto. ASTM Internacional.</mixed-citation>
				<element-citation publication-type="book">
					<person-group person-group-type="author">
						<collab>American Society for Testing and Materials</collab>
					</person-group>
					<year>2020</year>
					<source>ASTM C40/C40M-19. Método de prueba estándar para determinar impurezas orgánicas en agregado fino para concreto</source>
					<publisher-name>ASTM Internacional</publisher-name>
				</element-citation>
			</ref>
			<ref id="B18">
				<mixed-citation>Delgado, J. A. (2018). Curvas características de resistencia a compresión simple en concreto usando distintos tipos de cementos modificados. Proyecto final de graduación para optar por el título de Licenciatura en Ingeniería Civil, Escuela de Ingeniería Civil, Universidad de Costa Rica, San José, Costa Rica.</mixed-citation>
				<element-citation publication-type="thesis">
					<person-group person-group-type="author">
						<name>
							<surname>Delgado</surname>
							<given-names>J. A.</given-names>
						</name>
					</person-group>
					<year>2018</year>
					<source>Curvas características de resistencia a compresión simple en concreto usando distintos tipos de cementos modificados</source>
					<comment content-type="degree">Licenciatura</comment>
					<publisher-name>Escuela de Ingeniería Civil, Universidad de Costa Rica</publisher-name>
					<publisher-loc>San José, Costa Rica</publisher-loc>
					<publisher-loc>San José, Costa Rica</publisher-loc>
				</element-citation>
			</ref>
			<ref id="B19">
				<mixed-citation>Hernández, L. F. (2018). Resistencia a la compresión simple versus tiempo de curado en especímenes de concreto hidráulico usando cementos modificados. Proyecto final de graduación para optar por el título de Licenciatura en Ingeniería Civil, Escuela de ingeniería Civil, Universidad de Costa Rica , San José .</mixed-citation>
				<element-citation publication-type="thesis">
					<person-group person-group-type="author">
						<name>
							<surname>Hernández</surname>
							<given-names>L. F.</given-names>
						</name>
					</person-group>
					<year>2018</year>
					<source>Resistencia a la compresión simple versus tiempo de curado en especímenes de concreto hidráulico usando cementos modificados</source>
					<comment content-type="degree">Licenciatura</comment>
					<publisher-name>Escuela de ingeniería Civil, Universidad de Costa Rica</publisher-name>
					<publisher-loc>San José</publisher-loc>
				</element-citation>
			</ref>
		</ref-list>
	</back>
</article>